Maximum number of verification intervals: nLC = 3000
Full Scale Output: 2mV/V +/- 10%
Combined error: 0,017% of Full Scale Output (F.S.)
Temperature effect on zero: 0,0014% /°C
Temperature effect on full scale output: 0,0014% /°C
Compensated Temperature Range: -10°C/+40°C
Operating Temperature Range: -20°C/+60°C
Creep error after 30 minutes: 0,025% F.S.
Maximum tolerated excitation voltage: 15 VDC
Input Resistance: 410 ± 20 Ohm
Output Resistance: 350 ± 5 Ohm
Zero Balance: +/-10% F.S.
Insulation Resistance: >1000 MOhm
Safe Overload: 150% F.S.
Ultimate Overload: 200% F.S.
Nominal displacement: < 1mm
SPBC 6-wire shielded cable, 3m long, 5mm diameter
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.