Stainless steel approved shear beam load cells, suitable for creating CE-M approved scales with 4 load cells, or for weighing tanks and hoppers, with the aid of its accessories.
Technical Features
• Minimum load cell verification interval Vmin = EMax / 10.000
• Maximum number of verification intervals nLC = 3000
• Combined error 0,017% of Full Scale Output (F.S.)
• Full Scale Output 2mV/V +/- 0.5%
• Temperature effect on zero 0,002% / °C
• Temperature effect on full scale output 0,002% / °C
• Compensated Temperature Range -10°C/+50°C
• Operating Temperature Range -20°C/+60°C
• Creep error after 30 minutes 0,02% F.S.
• Maximum tolerated excitation voltage 15 VDC
• Input Resistance 1100 ± 20 Ohm
• Output Resistance 1000 ± 20 Ohm
• Insulation Resistance >5000 MOhm
• Safe Overload 150% F.S.
• Ultimate Overload 300% F.S.
• 6-wire shielded cable, 5m long, 5 mm diameter