Stainless steel approved shear beam load cells, suitable for creating CE-M approved scales with 4 load cells, or for weighing tanks and hoppers, with the aid of its accessories.Technical Features • Minimum load cell verification interval Vmin = EMax / 10.000 • Maximum number of verification intervals nLC = 3000 • Combined error 0,017% of Full Scale Output (F.S.) • Full Scale Output 2mV/V +/- 0.5% • Temperature effect on zero 0,002% / °C • Temperature effect on full scale output 0,002% / °C • Compensated Temperature Range -10°C/+50°C • Operating Temperature Range -20°C/+60°C • Creep error after 30 minutes 0,02% F.S. • Maximum tolerated excitation voltage 15 VDC • Input Resistance 1100 ± 20 Ohm • Output Resistance 1000 ± 20 Ohm • Insulation Resistance >5000 MOhm • Safe Overload 150% F.S. • Ultimate Overload 300% F.S. • 6-wire shielded cable, 5m long, 5 mm diameter